Comparison
of heatpumps in AHU´s Hemmes, Menerga, Dantherm e.a. |
|
|
Wanted dehumidification |
175 |
kg/hr |
NB: enthalpy of stale air kept at the same
value (thanks to aftercooler heatpump) |
|
|
|
Temp |
RH % |
x
abs g/kg |
|
Outside |
18 |
70 |
9 |
|
effic. Eplant |
0,4 |
|
Inside |
31 |
51 |
14,3 |
|
effic. therm |
0,9 |
|
supplytemperature |
31 |
|
|
|
100% outside air systems |
|
recirculating systems |
|
|
Hemmes |
Hemmes |
Menerga |
|
|
Menerga |
Gea Happ |
Dantherm |
Dantherm |
|
BH90 |
BH60 |
Men60 |
Hpu stale |
Vent60 |
Mecirc. |
|
|
|
|
90%+90% |
60%+60% |
2x60% |
0%wtw |
60%wtw |
2x60% |
circa60% |
0% 13,4degC |
0% 5 degC |
supply
x abs g/kg |
5,422 |
5,422 |
9 |
9 |
|
9 |
|
8,537556 |
5,409077 |
delta-x g/kg |
8,878 |
8,878 |
5,3 |
5,3 |
|
5,3 |
|
5,762444 |
8,890923 |
airflow required kg/hr |
19712 |
19712 |
33019 |
33019 |
|
33019 |
|
30369 |
19683 |
air flow required m3/h |
17386 |
17386 |
29123 |
29123 |
|
29123 |
|
26786 |
17360 |
|
|
|
|
cooler for dehumidification kWk |
54,1 |
78,6 |
|
|
166,0 |
|
277,3 |
269,5 |
heater
kWth (to same supplytemperature) |
7,7 |
40,5 |
29,0 |
122,0 |
|
44,5 |
|
152,0 |
144,5 |
stale air cooler kWc (to 25,43kJ/kg) |
79,1 |
87,3 |
157,6 |
248,1 |
|
|
COP chiller sec |
4,0 |
4,0 |
4,0 |
4,0 |
4,0 |
4,0 |
4,0 |
4,0 |
4,0 |
cooler for dehumidification E kWe |
13,5 |
19,7 |
|
|
41,5 |
|
69,3 |
67,4 |
stale air cooler E kWe |
19,8 |
21,8 |
39,4 |
62,0 |
|
|
|
|
|
|
condensorheat from dehumidification.
kWth |
67,6 |
98,3 |
|
|
207,4 |
|
346,6 |
336,8 |
condensorheat from stale air cooler kWth |
98,9 |
109,2 |
197,0 |
310,2 |
|
|
|
|
|
|
|
|
Netto for dehumidification |
|
|
|
Electra
kW |
13,5 |
19,7 |
0,0 |
0,0 |
|
41,5 |
|
69,3 |
67,4 |
heatsurplus kWth |
60,0 |
57,7 |
-29,0 |
-122,0 |
|
163,0 |
|
194,6 |
192,3 |
"COP heatpump" |
4,4 |
2,9 |
#DIV/0! |
#DIV/0! |
|
3,9 |
|
2,8 |
2,9 |
|
|
|
|
|
|
|
|
Netto
for dehumidification plus stale air cooler |
|
|
|
Electra
kW |
33,3 |
41,5 |
39,4 |
62,0 |
|
41,5 |
|
69,3 |
67,4 |
heatsurplus kWth |
158,8 |
166,9 |
168,0 |
188,1 |
|
163,0 |
|
194,6 |
192,3 |
"COP heatpump" |
4,77 |
4,02 |
4,26 |
3,03 |
|
3,93 |
|
2,81 |
2,85 |
(cop max= cop cooling +1) |
|
|
|
Heatfactor (useful surplus heat/used primary
source) |
1,91 |
1,61 |
1,71 |
1,21 |
|
1,57 |
|
1,12 |
1,14 |
|
|
|
|
evaporation of the pool is heat loss |
|
|
|
evaporation
of the pool kWth |
110 |
110 |
110 |
110 |
|
110 |
|
110 |
110 |
|
|
still to
consider : the exact fanenergy and the real COP considering the temperatures
of the cooling path. |
|
|
|
|
|
|
|
|
|
|
|